Electromagnetic Flow Meter !

SALIENT FEATURES
Suitable for conductive liquid
Absolutely maintenance free
Full bore type
Local indication through LCD
Simple & cost effective construction
Outstanding accuracy
Flow measurement in forward & reverse direction on demand
Empty pipe indication on demand
Material options depending upon process data
Universal power supply
Communication port on demand

Description

Suitable for conductive liquid absolutely maintenance free full bore type local indication through LCD simple & cost effective construction outstanding accuracy flow measurement in forward & reverse direction on demand empty pipe indication on demand material options depending upon process data universal power supply communication port on demand U-Mag are micro-controller full bore type electromagnetic flow transmitter specially used for various industrial applications. These flow transmitters accurately measure the flow rate of conductive liquids of slurries in closed pipes. Due to simple & rigid design, the flow transmitter in an obstruction less & maintenance free instrument in place of conventional mechanical flow measuring device. The use of 'pulsed dc technology offers highest ability & better measuring accuracy in the form of electrical signal 4-20 ma dc linearly proportional to volumetric flow. The instrument is based on faraday's law of electro-magnetic field generates a voltage that is proportional to the flow velocity, corresponding electrical output is provided with respect to measuring voltage.
Techinical Specification
Media : Liquid (Conductive) Process Pressure : 10 kg/cm2 max
Conductivity : > 5 p s/cm Material of Construction : Lining - Rubber / PTFE (Teflon)
Viscosity : 200 cp max : Flange - CS / MS /SS
Line Size : 15 NB to 600 NB : Electrode - SS 316L / Hastalloy C / Platinum
Excitation : Pulsed DC Coil : Coil Housing - MS / SS304
Type of output : 1) 40 to 20 mA DC, Isolated Power Supply : ) 24V DC, External
2) Pulse 2) 90-250 VAC, 50 Hz
Display : 16X2 LCD - 4 digit for Flow Rate & Power Construction : <10VA
8 digit for Tatalised Flow Isolation : 1.4 KV between Input, Output & Power Supply
Calibration : As per requirement (Factory Calibrated) Response Time : < 100mSec
Accuracy : +/- 0.5% F.S. (For 20 to 100% Flow) Temperature Coefficient : +/- 0.1% per OC
Linerity : +/- 0.5% Transmitter Enclosure : Flame proof, IP-65, IIA IIB CMRI certified
Repeatability : +/- 1% Process Connection : ASA 150 flange \, as per table B 16.5
Process Temp. : 70 oC Rubber/1500C PTFE Mounting : In Line (Horizontal OR Vertical)
Communication Port : On Demand Operating Conditions : Temperature 0 to 550 C
Humidity 5 to 95% on condensing